Showing results: 166 - 180 of 324 items found.
-
40-735-902-S3 -
Pickering Interfaces Ltd.
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
40-735-912 -
Pickering Interfaces Ltd.
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. This 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
40-735-902 -
Pickering Interfaces Ltd.
The 40-735 data communications multiplexer is designed for switching the data lines of serial interfaces (RS232, USB). Careful attention to the design of the module ensures that the switching system minimizes its impact on the transmission distance of USB1.1 interfaces. The MUX is available in 36:1 or 18:1 formats and enables a single source of serial data to be switched to one of 36 or 18 devices under test. This allows the data source to load information to, or receive information from, the device under test. The 36:1 version can be software configured into two independent 18 way MUXs enabling two separate sources of serial data to be connected to separate banks of 18 devices. The module is ideal for performing bulk testing of any device that relies on a serial data communications port to load software or control the device operation. It can also be used for a variety of other applications where ever a 2-pole low power MUX is required.
-
CHAMP-AV6 -
Curtiss-Wright Defense Solutions
The CHAMP-AV6 Quad DSP engine utilizes the 6U VPX-REDI format to unleash the tremendous I/O bandwidth of its eight NXP (formerly Freescale) Power Architecture MPC8640 processor cores (four 8640D dual-core processors). The local and off-board Serial RapidIO interfaces provide up to 10X the communications bandwidth that was achievable with the VME format.
-
PCI-COM2S And PCI-422/485-2 -
Acces I/O Products, Inc.
The PCI-COM2S and PCI-422/485-2 are dual-port, asynchronous serial communications cards designed for use in PCI-Bus computers. They are 6.5 inches (165 mm) long and may be installed in any 5V PCI slot in IBM and compatible computers. Each independent port supports RS-422 and RS-485 balanced-mode transmission/reception, and on the PCI-COM2S, RS-232 single-ended transmission/reception as well.
-
SI-60F -
LINEEYE Co., Ltd.
SI-60F is an interface converter to connect factory automation equipment and analyzers, which only have the RS-232C serial communication port, to LAN. The built-in Lantronix Xport® on the LAN interface converts RS-232C data into LAN protocol (TCP/IP). It is the environment-friendly design, such as low power consumption from DC5V and compact body (resource saving).
-
RMAC-VME -
Abaco Systems Inc
Designed for laboratory simulation and production test applications, the Modular Avionics Controller (RMAC) is an intelligent, high performance 6U VME product supporting ARINC protocols and other serial communications. As an evolutionary follow-on product to the successful VME-AIC product line, the RMAC-VME provides a single integrated interface to multiple avionics protocols on VMEbus platforms.
-
7406e -
Sealevel Systems, Inc.
The 7406e low profile PCI Express serial interface provides four RS-232 serial ports. For maximum compatibility with a wide range of peripherals, the board supports all standard RS-232 modem control signals. The serial ports utilize a 16C954 UART with 128-byte Tx/Rx FIFOs that enables data rates to 921.6K bps for reliable high-speed communications in data intensive applications. This high-performance UART includes 9-bit framing support and is fully software compatible with legacy 16550 applications. In addition, the board derives a 62.5 MHz clock from the PCI Express link. This ultra-high speed clock is divided by a flexible 8-bit clock prescalar with 1/8 steps to provide support for the widest range of standard and non-standard baud rates.
-
Type-C Tracker -
Ellisys Sàrl
Protocol and Electrical Analysis Tool for Type-C Communications Standards. All-in-One: Concurrent and tightly synchronized capture of USB Power Delivery protocol, Type-C voltage tracking (Vconn, Vbus, SBU, and CC), USB 2.0, Thunderbolt 3 UART and DisplayPort auxiliary (AUX) signaling over the Type-C SBU lines, alternate (ALT) mode support for DisplayPort, HDMI, and Thunderbolt, and capture and decoding of Serial Wire Debug (SWD) protocol, UART, Serial Peripheral Interface (SPI) I2C vendor-specific protocols, and Type-C Port Controller Interface traffic over I2C.
-
SonarMite 'Plus' App -
Ohmex Instruments
The SonarMite+ App is based on the free SonarMite App but offering additional features. The software is an Android App designed to work with the popular SonarMite Bluetooth Echo Sounder used in hydrographic surveying applications. With the demise of Hyperterminal as a standard terminal application the end user is left with little choice for a simple communications program with serial data devices. Connecting via Bluetooth is cleaner than USB cable, there are no wires and the connection is independent of baud rate and other serial port settings. Most terminal programs are not easily configured with commands to directly interface with instruments such as SonarMite.
-
DMC-1400 -
Martel Calibrators
The DMC-1400 Calibrator fully documents any calibration easily while performing the normal job. No special software is required! It features the ability to test for pass/fail criteria, measure and simulate thermocouples, RTDs, current, voltage, and frequency, and source pulse trains. PLCs, full fuseless protection, and a serial communications port for full control with ASCII commands.
-
HF (13.56 MHz) -
Balluff GmbH
BIS M uses the high frequency (HF) 13.56 MHz and supports the standard according to DIN ISO 15693 and 14443. Communication modules/gateways are used for the point-to-point or bus linking and are directly connected to a serial interface of a PC/a bus interface. The Subnet16 TM bus architecture supports a subnet of up to sixteen nodes via an RS485 interface.
-
CommFront Communications
CommFront offers a range of rugged, industrial-grade RS232 / RS485 / RS422 / TTL repeaters and hubs to meet serial communications' data distance needs by converting unbalanced signals to balanced ones, deploying repeaters to boost signal strength, and implementing hubs for star-configured connections, while still taking full advantage of cost-effective and readily-available copper wire.
-
LTI -
Dwyer Instruments Inc.
The Series LTI Temperature Panel Meters can be configured in a variety of configurations to provide visual indication and control of a process temperature. Field pluggable modules are available to add additional relay outputs, digital I/O ports, and serial communications. Utilizing an easy-to-read, dual 6-digit display, more descriptive programming parameters are displayed to simplify initial setup.
-
42-204-001 -
Pickering Interfaces Ltd.
The 40-204-001(PXI) and 42-204-001 (PXIe) are single channel differential multiplexers designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They are available with support for 1 or 2-channels of two wire serial interfaces. Each channel pair can be looped out to external equipment or the switches can be used simulate a channel open fault.